Yokogawa FU20 PH sensor

12mm widebody ORP sensor

SC25V PH21 sensor with warranty

원래 장소:

중국

브랜드 이름:

Yokogawa

모델 번호:

FU20

지금 챗팅하세요
인용 을 요청 하십시오
제품 세부 정보
메디아:
가스
포트 크기:
1/4 NPT
플랜지 재질:
316SST
표시하다:
옵션 LCD
범위:
0-10,000 psi
애플리케이션:
유압 시스템, 공정 제어, HVAC
인증:
CE, RoHS 규제
출력 신호:
4-20 MA
설치:
직접 또는 원격
다이어프램 재료:
316L 스테인리스 스틸
습식 재료:
스테인레스 스틸
프로세스 연결:
1/2인치 NPT
압력 제한:
최대 범위의 2 배
힘:
전기 같은
공급 전압:
10-30VDC
강조하다:

Yokogawa FU20 PH sensor

,

12mm widebody ORP sensor

,

SC25V PH21 sensor with warranty

지불 및 배송 조건
최소 주문 수량
1 PC
가격
USD 200
지불 조건
티/티
공급 능력
100 PC
제품 설명

What Are FU20 and FU24

  • Both FU20 and FU24 are combined pH + ORP (redox) sensors — they integrate multiple measurement elements (pH electrode, reference electrode, ORP (redox) electrode, and temperature sensor) in a single sensor body.
  • They are designed for industrial/liquid-analysis applications (water & wastewater treatment, chemical processing, power generation, etc.), where reliable measurement of pH and ORP (plus temperature compensation) is needed.

 

Key Design & Technical Features

  • Multi-element design: Each sensor includes a pH glass electrode, a saturated Ag/AgCl double-junction reference system, a solid platinum ORP electrode, and an integral Pt1000 for temperature measurement.
  • Robust body materials: The sensor bodies are made of chemically resistant materials (PPS 40GF / Ryton for FU20 and FU24; and sometimes PVDF for certain FU20 variants) to withstand harsh, aggressive or corrosive fluids.
  • Extended lifetime & reliability: The sensors use a double-junction reference system with a large volume polymerized electrolyte and a porous PTFE diaphragm to minimize poisoning or contamination of the reference — this prolongs the sensor life in demanding chemical environments.
  • Temperature compensation: Because of the built-in Pt1000 temperature sensor, pH and ORP measurements are automatically temperature-compensated, improving accuracy over a range of operating conditions.
  • Installation flexibility: These sensors can be installed in-line, as immersion probes, or off-line (in flow fittings). The FU20 especially supports quick-release adapters and easy removal for cleaning or calibration.

 

Differences: FU20 vs FU24 — When to Choose Which

Feature / Consideration

FU20

FU24

Typical application

General-purpose pH/ORP in liquids (water, wastewater, process fluids)

More demanding applications with varying pressure or temperature (harsh chemical environments)

Body material variants

Ryton/PPS 40GF or PVDF (depending on variant)

Ryton (PPS 40GF) chemical-resistant body

Reference system & protection

Double-junction reference, optionally with “Cation Differential” for longer life

Double-junction plus built-in pressure-compensation (bellows mechanism) — enhances stability under pressure/temperature fluctuations

Typical pH / ORP / Temperature range*

pH 0–14, ORP ~ –1500 to +1500 mV; temperature up to ~105 °C depending on variant

Same measurement ranges; designed to cope better with dynamic conditions (pressure/temperature swings)

* Exact operating limits may depend on sensor variant (dome vs flat, standard vs high-temperature, sample conductivity, etc.) — always check the manufacturer’s datasheet for your application conditions.

In short: use FU20 for standard, stable liquid conditions where ease of installation/maintenance and accuracy suffice; use FU24 when you expect pressure or temperature fluctuations, or chemical stress, and need maximum robustness and stability.

 

Typical Applications & Use Cases

  • Water and wastewater treatment — monitoring pH and ORP to control chemical dosing, disinfection, neutralization, etc.
  • Chemical-/process-industry streams — handling corrosive or aggressive fluids, requiring robust sensor construction.
  • Power generation / boiler-cooling / steam-cycle water — where pH/ORP must be monitored under variable temperature/pressure.
  • Industrial process control, water-treatment plants, neutralization tanks, or any setup needing simultaneous pH + redox (ORP) + temperature measurement with minimal maintenance.

 

Why Engineers / Industry Choose FU20 / FU24

  • Because they integrate pH, ORP, and temperature in a single compact sensor, reducing the number of probes needed and simplifying installation.
  • Because the double-junction reference + polymerized electrolyte + PTFE diaphragm significantly improves lifetime and reliability, even in chemically harsh or contaminated fluids.
  • Because of built-in temperature compensation, ensuring measurement accuracy over varying temperature; and in the case of FU24, built-in pressure compensation, ensuring stability under dynamic pressure or temperature conditions.
  • Because of versatility of installation (inline, immersion, flow-fitting, hot-tap possible with FU20), making them suitable for both new installations and retrofits.

 