인증:
CE, ROHS
HART 프로토콜:
사용 가능
맞춤형 지원:
OEM, ODM
참조 정확도:
표준 : 0.05% 백금 : 최대 0.025%
규약:
HART/RS485
모델:
510E
장착 유형:
나사산
장착 방법:
DIN 레일 또는 벽 마운트
범위:
0-10,000 psi
스팬 조정:
스팬의 ± 10%
플랜지 재료:
316SST
습식 재료:
스테인레스 스틸
압력 제한:
최대 범위의 2 배
장기 안정성:
연간 범위의 ± 0.1%
공급 전압:
10-30VDC
강조하다:

FMR20 radar level transmitter

,

Micropilot level measurement instrument

,

Time-of-flight radar for liquids

지불 및 배송 조건
최소 주문 수량
1 PC
가격
USD 500 1 pc
배달 시간
7-14 일
지불 조건
t/t
공급 능력
100 PC 1 주
제품 설명

What is Time-of-Flight Radar Level Measurement

Radar level measurement based on Time-of-Flight (ToF) is a non-contact method for determining the level of a liquid or solid in a vessel or open channel. The device emits short pulses of electromagnetic waves (microwave pulses), which travel to the surface of the material being measured, get reflected back, and are detected. The time the pulse takes to go and return (round-trip time) is proportional to the distance. Knowing the distance from the sensor to the surface, the level can be calculated (often subtracting from the maximum measurement distance).

Key advantages of ToF radar:

  • Non-contact: no parts submerged, so no issues with corrosion, build-up, fouling.
  • Works in harsh process conditions (vapors, dust, temperature, pressure).
  • Accurate and reliable.

 

Micropilot FMR20 — Overview

The Micropilot FMR20 is a level measurement instrument by Endress+Hauser using non-contact radar / Time-of-Flight principle.

Here are its main characteristics and applications:

Feature

Description

Measuring principle

Radar, Time-of-Flight. Emits microwave pulses (~26 GHz) and measures round-trip time to surface.

Applications

Continuous level measurement (liquids, and for simpler solids), and flow measurement via linearization (e.g. open channels, weirs) for utilities such as water & wastewater, mining, general industry.

Range / Max Measurement Distance

For liquid applications: up to ~15-20 m depending on antenna size / process connection. For solids: somewhat less.

Accuracy

For liquids: ±2 mm; for solids: ±5 mm under typical conditions.

Operating conditions

Temperature: -40 to +80 °C; Pressure: approx -1 to +3 bar overpressure.

Materials / Construction

PVDF housing, PBT parts; sealed and potted electronics to protect against moisture, ingress. Good for harsh environments.

Certifications / Protection class

IP66, IP68; NEMA 4X etc. Some versions have explosion protection approvals.

Communication / Configuration

2-wire output with HART (4-20 mA + digital), optional Bluetooth for configuration (SmartBlue app), remote displays.


How the Micropilot FMR20 Implements Time-of-Flight

Some specifics about how the FMR20 does ToF measurement:

  • Frequency: approx. 26 GHz (K-band). Higher frequency helps with better resolution and smaller beam widths.
  • Antenna / Beam-angle: Different antenna sizes (40 mm, 80 mm) which affect the beam divergence. Larger antenna gives narrower beam, which helps focusing and reduces interference from side reflections.
  • Blocking / Dead-zone: There is a minimum “blocking distance” or dead zone near the sensor where echoes cannot be reliably examined. The device has to ignore any signal echoes in that zone.
  • Signal processing: The FMR20 evaluates echo signals, filters out spurious reflections (from obstructions, internal vessel parts), possibly does mapping of echo strength vs time to ensure correct surface detection. It also does linearization when used for flow via open channels/weirs.

 

Strengths and Limitations

Strengths:

  • Very good accuracy for liquids (±2 mm).
  • Non-contact means low maintenance, no issues with material contact.
  • Suitable for a wide range of process conditions (temperature, pressure, contaminated or dusty vapors).
  • Wireless configuration (Bluetooth) + HART support for integration and set-up flexibility.

Limitations / things to pay attention to:

  • For solids or materials with low reflectivity, accuracy drops (±5 mm or more).
  • Need relatively clear line-of-sight; obstructions in beam path, turbulence, foam, vapors or heavy dust can interfere with echo detection.
  • Dead-zone near sensor: very near surface measurement might not be possible if within blocking distance.
  • Installation geometry matters: alignment, antenna shape, mounting height, etc.

 